CHAMERA-III

Chamera-III Power Station (3x77 MW) is a run of the river scheme with small pondage to harness the hydro power potential of river Ravi. It is located in Chamba district of Himachal Pradesh. The project comprises of a 64 m high, 73 m long concrete gravity dam with 6.5 m dia., 15.97 Km long head race tunnel. The underground power house with installed capacity of 231 MW houses 3 units of 77 MW capacity each designed to operate under the net rated head of 200 m and designed to generate 1108.17 million units in a 90% dependable year with 95% machine Availability. All the three generating units of the power station were commissioned in the month of June-2012. The beneficiary states/UTs of this power station are Uttarakhand, UP, Delhi, HP, Haryana, J&K, Punjab, Rajasthan and Chandigarh. The nearest rail head is Pathankot and nearest airport is Jammu. With the construction of the project, the area has also been benefitted by development of infrastructure, education, medical facilities and employment avenues.
Feature Name | Description |
---|---|
Location | Distt. Chamba (Himachal Pradesh) |
Approach | Nearest railhead - Pathankot (120 Km) Nearest Airport - Jammu (220 Km) |
Capacity | 231 MW (3 X 77 MW) |
Design Energy | 1108.17 MU (90% dependable year) |
Beneficiary States/UTs | Uttarakhand, UP, Delhi, HP, Haryana, J&K,MP, Punjab, Rajasthan , Chandigarh and Gujrat |
Date of Commercial Operation (COD) | U#1 - 04.07.2012; U#2 - 30.06.2012; U#3 - 30.06.2012 |
Dam | |
Type Height Length | Concrete gravity dam 64 m 73 m |
HRT | |
Shape | Horse shoe |
Diameter | 6.5 m |
Length | 15.970 Km |
Power House | |
Type | Underground |
Capacity | 231 MW (consisting 3 units of 77 MW each) |
Turbine: | |
Type | Francis |
Speed | 333 RPM |
Discharge/unit | 44 m3/sec |
No of Guide Vane | 20 |
Rated Head | 200m |
Generator | |
Rated continuous output | 85.560 MVA |
Rated Voltage | 11± 10% kV |
No of Poles | 18 |
Generator Step up Transformer: (GSU) | |
Type | Single Phase |
LV | 11 kV |
HV | 220/√3 kV |
MVA | 32 |
Type of cooling | OFWF |
GIS(Gas Insulated Switchgear) | 220 kV GIS |
TRT | |
Shape | Horse- shoe |
Diameter | 6.5 m |
Length | 125 m |
Evacuation of Power | 02 lines |
1. Chamera- III – Chamba Pooling Station | |
2. Chamera- III – Chamba Pooling Station |